Description
V5 Veterinary Anesthesia System( turbine-driven)
Comprehensive and innovative animal healthcare solution for anesthesia, ventilation and monitoring
Advantages of V5 Anesthesia Machine
1)Turbine-driven, reducing cylinder costs and hazards for animal hospitals.
2)10.2-inch foldable touchscreen suitable for veterinarians of different heights (especially suitable for customers in regions with taller average heights such as Northern Europe).
3)9 ventilation modes to meet the requirements of different animals.
4)Tidal volume as low as 2ml, better suited for the anesthesia needs of small animals.
5)Standard configuration includes three waveforms (P-t, V-t, F-t) and two loop displays (P-v, V-f), leading in its class.
6)Optional configurations such as oxygen generator, CO2, SpO2, oxygen cell, and AG to comprehensively ensure the safety of animal surgeries.
7)Supports OEM customization of your Logo, startup screen, etc.
8)Training support and software upgrade services.
9)CE certified, 2-year warranty.
Physical features
|
|
Machine size
|
1534*700*750 mm
|
Machine weight
|
55 kgs
|
Displays
|
10.2” TFT- LCD (touch screen),90-degree fold
|
Casters
|
4” slient casters with brake
|
Pneumatic systems
|
|
Gas source
|
Types: O2 and Air;or O2 Connector: DISS or NIST
|
Flowmeter
|
O2: 0 to 4 L/min; Air: 0 to 4 L/min
|
ACGO
|
Yes
|
O2 flush
|
25 to 75 L/min
|
Electrical
|
|
Input voltage
|
100-240V ~
|
Frequency
|
50/60Hz
|
Input Power
|
≤900 VA
|
Power cord
|
5m (different standards)
|
Battery
|
lithium battery*1
|
Nominal Voltage
|
14.4 VDC
|
Capacity
|
6600 mAh, supply
|
Anesthetic breathing system
|
|
Bellow
|
0~1600 ml,and 0~300 ml
|
Absorber canister
|
1600ml or 600ml
|
Heating function
|
Yes
|
Bypass function
|
No
|
Vaporizer
|
|
Type
|
Siriusmed: VP10 (Sevoflurane), VP20 (Isoflurane), VP40 (Halothane)
|
Number
|
1
|
Connector
|
Selectatec (optional)
|
Ventilator
|
|
Primary controls
|
Electronically controlled and electrically driven ventilator
|
Ventilation modes
|
VS, VCV, PCV, PRVC, SIMV-V, SIMV-P, SIMV-PRVCSOPNT/PSV(CPAP/PS), Backup(VCV/PCV)
|
System checks
|
Self-checking after startup
|
Patient type selection
|
Yes
|
Frequency
|
4~100bpm(VCV/PCV/PRVC),1~40 bpm(SIMV)
|
Tidal volumn
|
5-1600ml
|
IE ratio
|
4:1 to 1:10
|
PEEP
|
OFF, 3 ~ 30 cmH2O
|
Inspiratory time
|
0.1 ~ 10.0 s
|
Pressure Support
|
OFF, 3 ~ 50 cmH2O
|
Pressure Control
|
5 ~ 50 cmH2O
|
Flow trigger
|
0.5 ~ 20L/min
|
Pressure Trigger
|
-20 ~ -1 cmH2O
|
Inspiration termination level
|
5 ~ 80%
|
Tslope
|
0~2.0 s
|
Pressure limit
|
6 ~ 100 cmH2O
|
Monitor
|
|
Airway pressure
|
Peak, Pmean, Pplat, PEEP, Airway resistance, Pmin
|
IE ratio
|
9:1~1:99,±20%
|
Compliance
|
0 ~ 300 mL/cmH2O,±5 ml/cmH2O or ±20%
|
MV
|
0 ~ 60 L/min,±1 L/min or 15%,whichever is greater
|
Frequence
|
0 ~ 100 bpm,±1bpm or 10%,whichever is greater
|
Alrams types
|
Battery low/discharged, VT, MV, Airway pressure, Apnea,Frequence
|
Alrams time
|
0~120s
|
PriorItized alarms
|
Audible and Visual with Alarm classification ( warning ,caution, advisory )
|
Graph
|
Waves: P-t, V-t, F-t; Loops: P-V, P-F, V-F
|
Options
|
|
Optional
|
ETCO2, O2 sensor, oxygen concentrator
|
Reviews